Difference between revisions of "Operating CODESYS with softMC Guide Line"
Noam.nitzan (talk | contribs) |
Noam.nitzan (talk | contribs) |
||
Line 4: | Line 4: | ||
[[File:CODESYS.png|border|800px]] | [[File:CODESYS.png|border|800px]] | ||
<br/> | <br/> | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
Please download from the link received the following files: | Please download from the link received the following files: | ||
Line 11: | Line 16: | ||
* '''‘Configurator_archive_0.4.16.7.bndl’''' | * '''‘Configurator_archive_0.4.16.7.bndl’''' | ||
* ''''‘SN_UAC.LIB’''' | * ''''‘SN_UAC.LIB’''' | ||
+ | |||
+ | |||
+ | |||
+ | Please follow the steps below: | ||
+ | |||
+ | |||
+ | |||
+ | '''Part 1:''' | ||
+ | |||
+ | |||
+ | 1. Open ControlStudio. <br/> | ||
+ | 2. Connect to softMC7.<br/> | ||
+ | 3. please type in the terminal:<br/> | ||
+ | <pre> ?sys.information </pre> | ||
+ | :Check the ‘Maximum number of axes’. | ||
+ | :Please send a picture of the information. | ||
+ | 3. go to: | ||
+ | ::Tools -> Firmware Update -> choose the MC_FW.ZIP | ||
+ | 4. During the Firmware Update the MC will reboot twice.<br/> | ||
+ | 5. After the process ends, please check the new version by typing in the terminal: | ||
+ | <pre> ?sys.information </pre> | ||
+ | Now you should see (among rest): | ||
+ | * Version number: 0.4.16.7 <br/> | ||
+ | * Features: CODESYS:0x61131 <br/> | ||
+ | 6. Please provide: | ||
+ | * '''Hash number''' | ||
+ | * '''Serial number''' | ||
+ | * '''Maximum number of axes (from before the upgrade – after the upgrade it should be zero until installation of the UAC).''' | ||
+ | 7. Once you provide these details, you will receive UAC (User Authorization Code) and further instructions. |
Revision as of 16:26, 26 January 2017
CODESYS installation
Please download from the link received the following files:
- ‘MC_FW.ZIP’ - contains the firmware upgrade for softMC7 Multibus CODESYS
- ‘softMC_1_0_0_1.compiled-library’
- ‘Configurator_archive_0.4.16.7.bndl’
- '‘SN_UAC.LIB’
Please follow the steps below:
Part 1:
1. Open ControlStudio.
2. Connect to softMC7.
3. please type in the terminal:
?sys.information
- Check the ‘Maximum number of axes’.
- Please send a picture of the information.
3. go to:
- Tools -> Firmware Update -> choose the MC_FW.ZIP
4. During the Firmware Update the MC will reboot twice.
5. After the process ends, please check the new version by typing in the terminal:
?sys.information
Now you should see (among rest):
- Version number: 0.4.16.7
- Features: CODESYS:0x61131
6. Please provide:
- Hash number
- Serial number
- Maximum number of axes (from before the upgrade – after the upgrade it should be zero until installation of the UAC).
7. Once you provide these details, you will receive UAC (User Authorization Code) and further instructions.