Difference between revisions of "EtherCAT:EC GET IO MODULE IN OUT"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "Axystems:" to "")
Line 2: Line 2:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
This function returns an IO module's input/ output setting.  set (ON -1) or unset (OFF - 0)
+
This function returns an IO module's input/ output setting.  set (ON -1) or unset (OFF - 0)<br/>
 +
It is easier to query Digital I/O's if they are associated with System's digital I/O's.<br/>
 +
Please refer to [[EtherCAT:DIGITAL-IOS|Digital I/O's]] for more information.<br/>
  
 
|INPUT=
 
|INPUT=

Revision as of 13:11, 23 October 2014

This function returns an IO module's input/ output setting. set (ON -1) or unset (OFF - 0)
It is easier to query Digital I/O's if they are associated with System's digital I/O's.
Please refer to Digital I/O's for more information.

Input

Slave address, PDO index, PDO sub-index.

Output

None

Return Value

The input/output is set - the function returns 1. The input/output is unset - the function returns 0.

Declaration

public function EC_GET_IO_MODULE_IN_OUT(byval slaveaddress as long, byval index as long, byval subindex as long) as long

Syntax

retVal = EC_GET_IO_MODULE_IN_OUT(<Slave address>, <PDO index>, <PDO sub-index>)

Examples

retVal = EC_GET_IO_MODULE_IN_OUT(1, 0x7020, 0x01)