== Step 1: Declare Axis ==
 
== Step 1: Declare Axis ==
 
 
In the first line of CONFIG.PRG file write the number of axes that will be in use:
 
In the first line of CONFIG.PRG file write the number of axes that will be in use:
 
 
<pre>
 
<pre>
 
Sys.Naxes = <number>
 
Sys.Naxes = <number>
Line 16: Line 14:
 
End Program
 
End Program
 
</pre>
 
</pre>
 
  
 
Send this file to MC and run it by issuing these two lines from terminal window:
 
Send this file to MC and run it by issuing these two lines from terminal window:
Line 31: Line 28:
  
 
== Step 2: Setting Meaningful Axis Name ==
 
== Step 2: Setting Meaningful Axis Name ==
 
 
System default axis names are not very user friendly (a1,a2,a3, etc.).
 
System default axis names are not very user friendly (a1,a2,a3, etc.).
 
It is a good practice to give them more meaningful names. This is done in CONFIG.PRG file only, by assigning a new name to each axis (no double-quotes) to [[MC-Basic:axis.AXISNAME|<axis>.AxisName]] property.
 
It is a good practice to give them more meaningful names. This is done in CONFIG.PRG file only, by assigning a new name to each axis (no double-quotes) to [[MC-Basic:axis.AXISNAME|<axis>.AxisName]] property.
 
 
<pre>
 
<pre>
 
Sys.Naxes = <number>
 
Sys.Naxes = <number>
Line 84: Line 79:
  
 
:*Linear axes:
 
:*Linear axes:
::For position in milli-meters PositionFactor is:PFAC = Pos_Units)/MPITCH
+
::For position in millimeters PositionFactor is:PFAC = Pos_Units)/MPITCH
  
 
[[Image:LinMotor.png|LinMotor.png]]
 
[[Image:LinMotor.png|LinMotor.png]]
Line 90: Line 85:
 
See Motion Bus setup for pos_units and MPITCH setup
 
See Motion Bus setup for pos_units and MPITCH setup
  
==Step#5: Moving Direction==
+
==Step 5: Moving Direction==
 
 
 
Positive direction of drive's position increments does not have to match the desired positive direction of user axis (Upwards, Left-Right, Counterclockwise). Therefore <axis>.direction flag is to be used:
 
Positive direction of drive's position increments does not have to match the desired positive direction of user axis (Upwards, Left-Right, Counterclockwise). Therefore <axis>.direction flag is to be used:
 
 
<pre>
 
<pre>
 
<axis>.Direction = {1|-1}
 
<axis>.Direction = {1|-1}
 
</pre>
 
</pre>
 
  
 
Value of '''-1''' indicates direction inversion.
 
Value of '''-1''' indicates direction inversion.
  
==Step#6: Velocity, Acceleration, Jerk units ==
+
==Step 6: Velocity, Acceleration, Jerk Units ==
 +
Velocity/acceleration/jerk units do not have to match position units. The user may select the units. For all the derivative units (velocity, acceleration, jerk), the default time scale is in milliseconds; therefore scaling is needed.
  
Velocity units do not have to match position units (same for acceleration, jerk). User is free to select his/hers own units. For all the derivative units (velocity, acceleration, jerk) the default time scale  is in milli-seconds, therefore scaling is needed.
+
To use position units per second for velocity the following must be defined:
 
 
To use position units per second for velocity one needs to define:
 
 
     '''<axis>.VelocityFactor = <axis>.PositionFactor/1000'''
 
     '''<axis>.VelocityFactor = <axis>.PositionFactor/1000'''
In this case if the user set the position in mm the velocity will be in '''mm/sec'''
+
In this case if the user sets the position in millimeters the velocity will be '''mm/sec'''
  
 
To define velocity in '''RPM''' of the motor:<br>
 
To define velocity in '''RPM''' of the motor:<br>
 
     '''<axis>.VelocityFactor = Pos_Units /1000/60'''
 
     '''<axis>.VelocityFactor = Pos_Units /1000/60'''
  
For acceleration and jerk units is the same, their default values are expressed in velocity and acceleration units per milli-seconds. So in order to set them per seconds one needs to set them as:
+
Acceleration and jerk units are the same; their default values are expressed in velocity and acceleration units per milliseconds. Thus, in order to set them per seconds, they need to be set as:
 
     '''<axis>.AccelerationFactor = <axis>. VelocityFactor /1000'''
 
     '''<axis>.AccelerationFactor = <axis>. VelocityFactor /1000'''
 
     '''<axis>.JerkFactor        = <axis>. AccelerationFactor /1000'''
 
     '''<axis>.JerkFactor        = <axis>. AccelerationFactor /1000'''
  
 
+
==Step 7: Units Summary==
==Step#7:Units summary==
 
 
 
 
Position, velocity, acceleration and jerk units are set by:
 
Position, velocity, acceleration and jerk units are set by:
 +
:'''<axis>.PositionFactor = …'''
 +
:'''<axis>.Direction = …'''
 +
'''<axis>.VelocityFactor = ..'''
 +
:'''<axis>.AccelerationFactor = ..'''
 +
:'''<axis>.JerkFactor = …'''
  
  '''<axis>.PositionFactor = …'''
+
==Step 8: Position Limits==
  '''<axis>.Direction = …'''
 
  '''<axis>.VelocityFactor = ..'''
 
  '''<axis>.AccelerationFactor = ..'''
 
  '''<axis>.JerkFactor = …'''
 
 
 
==Step#8:Position Limits==
 
 
Setting  position range of an axis.
 
Setting  position range of an axis.
 
Setting max position:
 
Setting max position:
Line 144: Line 132:
 
  <axis>. PositionRollOverMin
 
  <axis>. PositionRollOverMin
  
Not that if the enable flag is not set the correspondent  value does not need to be set.
+
Note: If the enable flag is not set, the corresponding value does not need to be set.
  
 
[[Image:Axis-PLIM.PNG|500px]]
 
[[Image:Axis-PLIM.PNG|500px]]
  
==Step#9: Motion Bus Units Setup==
+
==Step 9: Motion Bus Units Setup==
 
+
Depending on the type of motion bus (EtherCAT, SERCOS, CANopen) and drive used, several parameters are available for the user to adjust (but are not necessarily needed):
Depending on the type of Motion-Bus (EtherCAT, SERCOS, CanOpen) and drive used there are several parameters available for the user to be adjusted (not necessarily needed):
 
 
 
In case micro-interpolation is turned on in the drive, the velocity sent to drive must be properly scaled, this is done with (for counts per ms):
 
  '''<axis>.MotionBusVelocityScale = 0'''
 
  '''<axis>.MotionBusVelocityBase = 1'''
 
In case a limited drive’s position range is used (other then integer 32 bits):
 
  '''<axis>.CountMin = < drive min position value>'''
 
  '''<axis>.CountMax = < drive max position value>'''
 
  
==Step#10: Motion Parameters==
+
If micro-interpolation is turned on in the drive, the velocity sent to drive must be properly scaled; this is done with (for counts per ms):
 +
:'''<axis>.MotionBusVelocityScale = 0'''
 +
:'''<axis>.MotionBusVelocityBase = 1'''
 +
If a limited drive’s position range is used (other then integer 32 bits):
 +
:'''<axis>.CountMin = < drive min position value>'''
 +
:'''<axis>.CountMax = < drive max position value>'''
  
Motion parameters are grouped into velocity, acceleration and jerk values. They all have their max values for overall limitations, and their motion-default values that are used when motion is executed.
+
==Step 10: Motion Parameters==
 +
Motion parameters are grouped into velocity, acceleration and jerk values. All have maximum values for overall limitations, and motion-default values that are used when motion is executed.
  
 
{| class="wikitable" style="float:right; margin-left: 10px; color: red; border-style: solid; border-width: 3px"
 
{| class="wikitable" style="float:right; margin-left: 10px; color: red; border-style: solid; border-width: 3px"
Line 186: Line 172:
 
   <axis>.JerkMax
 
   <axis>.JerkMax
  
==Step#11: Safety Parameters==
+
==Step 11: Safety Parameters==
 
Maximum allowed position error (PE). PE is defined as a difference between the position command and position feedback. Due to communication delay of the motion bus and processing time of the drive (micro-interpolation) position command of the several samples before the current is compared to the currently obtained position feedback of the drive:
 
Maximum allowed position error (PE). PE is defined as a difference between the position command and position feedback. Due to communication delay of the motion bus and processing time of the drive (micro-interpolation) position command of the several samples before the current is compared to the currently obtained position feedback of the drive:
 
   <axis>.PositionErrorMax – max allowed position error during in user units.
 
   <axis>.PositionErrorMax – max allowed position error during in user units.
Line 200: Line 186:
 
   <axis>.TorqueMaxError
 
   <axis>.TorqueMaxError
  
==Step#11: Smoothness==
+
==Step 12: Smoothness==
  
 
Different profile types are available from very smooth S-curves (Acceleration Trapeze, Sine Acceleration) to less smooth by faster Velocity Trapeze, to totally edgy profiles (Constant Velocity) by setting these two parameters:
 
Different profile types are available from very smooth S-curves (Acceleration Trapeze, Sine Acceleration) to less smooth by faster Velocity Trapeze, to totally edgy profiles (Constant Velocity) by setting these two parameters:
Line 207: Line 193:
 
<axis>.PrfType specifies profile more precisely (Velocity Trapeze, Acceleration Trapeze, Sine Acceleration)
 
<axis>.PrfType specifies profile more precisely (Velocity Trapeze, Acceleration Trapeze, Sine Acceleration)
  
==Step#12: Axis Setup Complete Example - the SetAxis subroutine==
+
==Step 13: Axis Setup Complete Example - the SetAxis Subroutine==
  
 
<pre>
 
<pre>
Line 242: Line 228:
 
end sub
 
end sub
 
</pre>
 
</pre>
==Step#13: Motion-Bus EtherCat example ==
+
==Step 14: Motion-Bus EtherCAT Example ==
  
 
Position Units
 
Position Units
Line 253: Line 239:
 
::gear ratio = FBGMS / FBGDS
 
::gear ratio = FBGMS / FBGDS
  
==Step#14: Extra - Dynamic model ==
+
==Step 15: Extra - Dynamic Model ==
  
  

Revision as of 06:43, 19 August 2014

Introduction

This series of slides will explain how to create and set an axis in the softMC controller. For that you will need:

  • Running softMC (either a real, or virtual)
  • User interface (Control.Studio)

Step 1: Declare Axis

In the first line of CONFIG.PRG file write the number of axes that will be in use:

Sys.Naxes = <number>
…
Program
…
End Program

Send this file to MC and run it by issuing these two lines from terminal window:

send config.prg
reset all

Now you have your axes defined, it is easily to check issuing this command from terminal window:

->?axislist
A1,A2,A3,A4,A5,A6,A7,A8,A9,A10,A11,A12,A13,A14,A15,A16,A17

Step 2: Setting Meaningful Axis Name

System default axis names are not very user friendly (a1,a2,a3, etc.). It is a good practice to give them more meaningful names. This is done in CONFIG.PRG file only, by assigning a new name to each axis (no double-quotes) to <axis>.AxisName property.

Sys.Naxes = <number>
…
Program
	a1.AxisName = Xaxis
	a2.AxisName = Lift
…
End Program

Step 3: Preparing General Axis Setup

To set up system axes, a setup program must be prepared. Let’s call it SETUP.PRG.</br> It is important to know:

  • To access (write to) an axis property, the axis needs to be attached.
  • For some properties, the axis needs to be disabled

SETUP.PRG

Program
	Call SetAxis(a1)
	Call SetAxis(a2)	
	…
End Program

Sub SetAxis(ax as generic  axis)
With ax
	Attach
		En = 0
		…
		<stuff goes here>
		…
	Detach
End With
End Sub

Step 4: Position Units Definition

GearMotor.png

<axis>.PositionFactor defines the position units that will be used in all position variables of the specified axis (pcmd, pfb, etc.). It consists of:

  • Motor encoder resolution seen through the motion-bus (See EtherCAT, SERCOS, CanOPEN). How many counts are there in one motor revolution - stored in pos_units global variable (for each axis differently).
  • Gear ratio (M:N) and/or the pitch of the linear screw (mm/rev).
  • Rotary axes:
For position in degrees PositionFactor is:PFAC = Pos_Units *(M/N)/360
  • Linear axes:
For position in millimeters PositionFactor is:PFAC = Pos_Units)/MPITCH

LinMotor.png

See Motion Bus setup for pos_units and MPITCH setup

Step 5: Moving Direction

Positive direction of drive's position increments does not have to match the desired positive direction of user axis (Upwards, Left-Right, Counterclockwise). Therefore <axis>.direction flag is to be used:

	<axis>.Direction = {1|-1}

Value of -1 indicates direction inversion.

Step 6: Velocity, Acceleration, Jerk Units

Velocity/acceleration/jerk units do not have to match position units. The user may select the units. For all the derivative units (velocity, acceleration, jerk), the default time scale is in milliseconds; therefore scaling is needed.

To use position units per second for velocity the following must be defined:

   <axis>.VelocityFactor = <axis>.PositionFactor/1000

In this case if the user sets the position in millimeters the velocity will be mm/sec

To define velocity in RPM of the motor:

    <axis>.VelocityFactor = Pos_Units /1000/60

Acceleration and jerk units are the same; their default values are expressed in velocity and acceleration units per milliseconds. Thus, in order to set them per seconds, they need to be set as:

    <axis>.AccelerationFactor = <axis>. VelocityFactor /1000
    <axis>.JerkFactor        = <axis>. AccelerationFactor /1000

Step 7: Units Summary

Position, velocity, acceleration and jerk units are set by:

<axis>.PositionFactor = …
<axis>.Direction = …

<axis>.VelocityFactor = ..

<axis>.AccelerationFactor = ..
<axis>.JerkFactor = …

Step 8: Position Limits

Setting position range of an axis. Setting max position:

<axis>.Pmax = … and enabling /disabling it: <axis>.PmaxEn = {0|1}

Setting min position:

<axis>.Pmin = … and enabling /disabling it: <axis>.PminEn = {0|1}

Setting the axis type:

<axis>.AxisType = 0 ‘ For linear axes
<axis>.AxisType = 1 ‘ For rotary axes

For rotary axes rollover can be defined: Enabling/Disabling it:

<axis>.PositionRollOverEnable  = {0|1}

Setting the whole range:

<axis>. PositionRollOver

Setting the low value:

<axis>. PositionRollOverMin

Note: If the enable flag is not set, the corresponding value does not need to be set.

Axis-PLIM.PNG

Step 9: Motion Bus Units Setup

Depending on the type of motion bus (EtherCAT, SERCOS, CANopen) and drive used, several parameters are available for the user to adjust (but are not necessarily needed):

If micro-interpolation is turned on in the drive, the velocity sent to drive must be properly scaled; this is done with (for counts per ms):

<axis>.MotionBusVelocityScale = 0
<axis>.MotionBusVelocityBase = 1

If a limited drive’s position range is used (other then integer 32 bits):

<axis>.CountMin = < drive min position value>
<axis>.CountMax = < drive max position value>

Step 10: Motion Parameters

Motion parameters are grouped into velocity, acceleration and jerk values. All have maximum values for overall limitations, and motion-default values that are used when motion is executed.

Motion default value is: <axis>.VelocityCruise

Velocity is set according to maximum axis physical limit (drives/motor capabilities and mechanical limitations):

 <axis>.Vmax 
Motion default values are: <axis>.Acceleration
<axis>.Deceleration

Acceleration is set according to maximum axis physical limits (Max drive/motor current, axis load) in user units:

 <axis>.Amax
 <axis>.Dmax
Motion default value is: <axis>.Jerk

Jerk is the third time-derivation of position, if smooth profiles are used it needs to be defined a good rule of thumb is to set J=BW*A, where J – jerk, A – acceleration, BW- control Bandwidth (Hz).

 <axis>.JerkMax

Step 11: Safety Parameters

Maximum allowed position error (PE). PE is defined as a difference between the position command and position feedback. Due to communication delay of the motion bus and processing time of the drive (micro-interpolation) position command of the several samples before the current is compared to the currently obtained position feedback of the drive:

 <axis>.PositionErrorMax – max allowed position error during in user units.
 <axis>.PositionErrorDelay – number of samples used for delay computation.

Velocity (Runaway) Protection, the feedback velocity of the motor is checked every sample (recommended to be set to 120% of the <axis>.VelocityMax)

 <axis>.VelocityOverSpeed

Sanity Threshold, as a final protection against unintentional jumps (recommended to be set to 1000% of <axis>.VelocityMax):

 <axis>.VelocitySafetyLimit

Torque Error – only if axis dynamic model is turned on

 <axis>.TorqueMaxError

Step 12: Smoothness

Different profile types are available from very smooth S-curves (Acceleration Trapeze, Sine Acceleration) to less smooth by faster Velocity Trapeze, to totally edgy profiles (Constant Velocity) by setting these two parameters:

<axis>.Smooth defined automatic (0-100) or manual smoothing (-1) <axis>.PrfType specifies profile more precisely (Velocity Trapeze, Acceleration Trapeze, Sine Acceleration)

Step 13: Axis Setup Complete Example - the SetAxis Subroutine

sub SetRotAxis(ax as generic axis, byval minval as double , byval maxval as double)
  with ax
    attach
      En = 0
      AxisType = 1
      PositionFactor = pos_unit/360
      VelocityFactor = PositionFactor /1000
      AccelerationFactor = VelocityFactor /1000
      Jerkfactor = AccelerationFactor /1000
      VelocityMax = 1000
      AccelerationMax = 10000
      DecelerationMax= 10000
      JerkMax = 20*amax
      VelocityCruise = 0.5*VelocityMax
      Acceleration = AccelerationMax 
      Deceleration = DecelerationMax
      Jerk = JerkMax 
      PrfType = -1
      Smooth = -1
      VelocityOverspeed = 1.2*VelocityMax
      VelocitySafetyLimit = 10*VelocityMax
      PositionErrorDelay = 2
      PositionErrorMax  = 1
      PositionMax = maxval
      PositionMin = minval
      PositionMaxEn = 1
      PositionMinEn = 1
      PositionRolloverEnable = 0
   detach
  end with
end sub

Step 14: Motion-Bus EtherCAT Example

Position Units

First read the motor encoder resolution (MENCRES – SDO:0x20F1:0)
MENCRES = EC_SDO_READ(<addr>,0x20f1,0)

Then set (value of 1) the configured number of motor shaft revolutions and number of driving shaft revolutions. The gear ratio is calculated by the following:

Fieldbus CANopen Gear Motor Shaft Scaling (FBGMS – SDO0x2091:0)
Fieldbus CANopen Gear Driving Shaft Scaling (FBGDS – SDO0x2091:1)
gear ratio = FBGMS / FBGDS

Step 15: Extra - Dynamic Model

Torque Scaling

<axis>.TorqueFactor – according to the Motor KT parameter

Limits

<axis>.TorqueMax – maximum motor torque

Dynamic Model Parameters

axis.DYNAMICMODEL[..] = <…>