Difference between revisions of "MC-Basic:robot.VELOCITYSYNCROT"

From SoftMC-Wiki
Jump to: navigation, search
Line 40: Line 40:
  
 
}}
 
}}
[[Category:Axystems:Motion:MovingFrame]]
+
[[Category:Motion:MovingFrame]]

Revision as of 09:18, 22 May 2014

Limits robot velocity of the rotational moving frame componenet during synchronization process (from the time tracking is started (e.g. Slave=5) until it is synchronized with moving frame <robot>.IMFS = 1)

Syntax

<ROBOT>.VelocitySyncRot = <numeric expression>

Availability

Since Version 4.0.22

Type

Double

Range

0 to MaxDouble

Units

deg/sec

Default

4000

Scope

Configuration, Task or Terminal

Limitations

Read/Write, Modal Only

Examples

Scara.VelocitySyncRot = 500

See Also