DecStopRot present the rotation stopping deceleration in case of stop command from type DecStopOnPath. This value is used when stop interrupts to a Robot movement from type Circle or MoveS..
Short form
<ROBOT>.DecStopRot
Syntax
<ROBOT>.DECELERATIONSTOPROT = <value>
Availability
Since Version 4.2.x
Type
Double
Range
0.01 to Max Double
Units
deg/sec2
Default
4e4 * pi/180
Scope
Terminal or task
Limitations
Read/Write . Modal Only. Robot property only.
Examples
<ROBOT>.DECELERATIONSTOPROT = 5000