Difference between revisions of "AXY:MC-Basic:group.VELOCITYFACTOR"
m (Miborich moved page Axystems:MC-Basic:group.VELOCITYFACTOR to MC-Basic:group.VELOCITYFACTOR: Global renaming of Axystems: namespace into (Main):) |
|
(No difference)
| |
Revision as of 08:51, 22 May 2014
This property specifies the conversion factor between the user velocity units and the internal units [counts per msec].
| NOTE | |
| In using VELOCITYFACTOR for a group, the position units are taken from the POSITIONFACTOR of the axes within the group. The position units must not be specified in the group’s VELOCITYFACTOR. |
Short form
<group>.Vfac
Syntax
<group>.VelocityFactor = <expression>
?<group>.VelocityFactor
Availability
All versions
Type
Double
Range
Greater than zero
Default
1/60000 (for working in units of position units per minute)
Scope
Configuration, Task or Terminal
Limitations
Cannot be changed while axis is enabled or while axis is set up as a master axis.
To set the value within a task, the group must be attached to that task (using the ATTACH command).
Examples
G1.Vfac = 1 / 60000 ‘work in per minute
G1.Vfac = 1 / 1000 ‘work in per second