Difference between revisions of "MC-Basic:group.DECELERATIONSTOP"
Line 37: | Line 37: | ||
|SEE ALSO= | |SEE ALSO= | ||
* [[MC-Basic:axis.DECELERATIONSTOP|axis.DECELERATIONSTOP]] | * [[MC-Basic:axis.DECELERATIONSTOP|axis.DECELERATIONSTOP]] | ||
− | * [[ | + | * [[MC-Basic:group.ACCELERATION|group.ACCELERATION]] |
* [[Axystems:MC-Basic:group.ACCELERATIONMAXgroup.DECELERATION|group.ACCELERATIONMAXgroup.DECELERATION]] | * [[Axystems:MC-Basic:group.ACCELERATIONMAXgroup.DECELERATION|group.ACCELERATIONMAXgroup.DECELERATION]] | ||
* [[Axystems:MC-Basic:group.DECELERATIONMAX|group.DECELERATIONMAX]] | * [[Axystems:MC-Basic:group.DECELERATIONMAX|group.DECELERATIONMAX]] |
Revision as of 08:49, 22 May 2014
DecStop present the stopping deceleration in case of stop command from type DecStopOnPath. An additional use is done in internal system stopping procedure as when kill-task is operated (and slave=0 is given when conveyer tracking is on). This value is used when stop interrupts the next cases -single axis movement, or group movement from type Move or Circle.
Short form
<group>.DecStop
Syntax
<group>.DecelerationStop = <value>
Type
Double
Read/Write
Range
0.01 to Max Double
Units
Acceleration user units
Default
1000
Scope
Terminal or task
Limitations
Modal Only.
Examples
Group1.DecStop = 1000