This property is used to multiply the POSITIONEXTERNALFACTOR and VELOCITYEXTERNALFACTOR in order to determine the sign of the external encoder input.

Short form

<axis>.DirExt

Syntax

<axis>.DirectionExternal  = <expression>
?<axis>.DirectionExternal

Availability

All versions

Type

Integer

Range

-1 or 1

Default

1

Scope

Configuration, Task or Terminal

Limitations

The axis must be disabled to set the property. Within a task, the specified axis must be attached in order to set it.

Examples

A1.DirExt = 1     ' Setting external direction to a positive value

?A1.DirExt        ' Querying the external value

See Also