Difference between revisions of "MC-Basic:axis.TORQUEERRORDISABLETYPE"

From SoftMC-Wiki
Jump to: navigation, search
Line 47: Line 47:
 
* [[Axystems:MC-Basic:axis.TORQUEERRORSTOPTYPE|axis.TORQUEERRORSTOPTYPE]]
 
* [[Axystems:MC-Basic:axis.TORQUEERRORSTOPTYPE|axis.TORQUEERRORSTOPTYPE]]
 
* [[MC-Basic:axis.TORQUEERRORFILTER|axis.TORQUEERRORFILTER]]
 
* [[MC-Basic:axis.TORQUEERRORFILTER|axis.TORQUEERRORFILTER]]
* [[Axystems:MC-Basic:axis.TORQUEERRORMAX|axis.TORQUEERRORMAX]]
+
* [[MC-Basic:axis.TORQUEERRORMAX|axis.TORQUEERRORMAX]]
 
* [[MC-Basic:axis.TORQUEERROR|axis.TORQUEERROR]]
 
* [[MC-Basic:axis.TORQUEERROR|axis.TORQUEERROR]]
  

Revision as of 08:48, 22 May 2014

Defines the torque-error collision procedure. If the TE > TEMAX axis is disabled after it is stopped by the stop profile defined by TorqueErrorStopType, according to values of TorqueErrorDisableType:

0 normal

1 high-power

2 TBD

Short form

<axis>.TorqueErrorDisableType

Syntax

?<axis>. TorqueErrorDisableType

Availability

Since Version 4.5.x

Type

Integer

Range

0 to 2

Default

0

Scope

Configuration, Task or Terminal

Limitations

Read/Write only, Modal Only

Examples

?A1.TorqueErrroDisableType

See Also