Difference between revisions of "MC-Basic:SYSTEM.IPADDRESSMASK"
m |
|||
Line 50: | Line 50: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:ACCEPT|ACCEPT]] |
* [[Axystems:MC-Basic:CLOSE|CLOSE]] | * [[Axystems:MC-Basic:CLOSE|CLOSE]] | ||
* [[Axystems:MC-Basic:CONNECT|CONNECT]] | * [[Axystems:MC-Basic:CONNECT|CONNECT]] |
Revision as of 08:35, 22 May 2014
Sets or queries the IP address and subnet mask for the Ethernet interface. The system performs a primary test to ensure that the address and subnet mask match. Manual changing of the IP address or subnet mask may stop communication between ControlStudio and the softMC. When IP address is set to “dhcp”, softMC will try to connect DHCP server and obtain IP address.
IMPORTANT | |
Manually changing the IP address or mask may stop communication between ControlStudio and the softMC. |
Syntax
Sys.IPAddressMask=<address:mask>
System.IPAddressMask=<address:mask>
System.IPAddressMask=<dhcp>
?Sys.IPAddressMask
?System.IPAddressMask
Availability
All versions
Type
String
Scope
Set in Configuration only, Query in Task or Terminal
Limitations
Set from Config.prg. Changing of the IP address and/or subnet mask from the terminal may lead to a lost connection between the controller and ControlStudio. This is applicable only for Ethernet interfaces. You must close all open connections before changing the IP address or subnet mask.
Examples
?Sys.IPAddressMask
sys.IPAddressMask=”212.25.84.109:255.255.255.128”
Sys. IPAddressMask=”dhcp”