Difference between revisions of "MC-Basic:axis.RTCB1 MODE"
m |
m |
||
Line 11: | Line 11: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
In SERCOS, a realtime control bit is set to activate a function by writing the IDN of that function to IDN 301. This property encapsulates that operation by enabling you to specify (<''value''>) of the IDN number of the function to be activated. This is useful for CAPTURE, for example, where IDN 405 is used to arm the capture. | In SERCOS, a realtime control bit is set to activate a function by writing the IDN of that function to IDN 301. This property encapsulates that operation by enabling you to specify (<''value''>) of the IDN number of the function to be activated. This is useful for CAPTURE, for example, where IDN 405 is used to arm the capture. | ||
− | |||
− | |||
− | |||
− | |||
Line 33: | Line 29: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | Can only be set during SERCOS communications phase 4 | + | *Can only be set during SERCOS communications phase 4 |
+ | *Not supported in EtherCAT system | ||
|EXAMPLE= | |EXAMPLE= |
Revision as of 12:41, 26 March 2014
In SERCOS, a realtime control bit is set to activate a function by writing the IDN of that function to IDN 301. This property encapsulates that operation by enabling you to specify (<value>) of the IDN number of the function to be activated. This is useful for CAPTURE, for example, where IDN 405 is used to arm the capture.
Syntax
<axis>.RTCB1_Mode = <value>
Availability
All versions
Type
Long
Range
Any IDN that can be activated using this mechanism.
Scope
Configuration, Task or Terminal
Limitations
- Can only be set during SERCOS communications phase 4
- Not supported in EtherCAT system
Examples
a1.rtcb1_mode = 405
- arm capture using RTCB #1