Difference between revisions of "MC-Basic:axis.IN3MODE"

From SoftMC-Wiki
Jump to: navigation, search
m
Line 10: Line 10:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
 
 
 
 
Specifies the functionality of the drive digital input 3.<br>
 
Specifies the functionality of the drive digital input 3.<br>
 
0 – no special function<br>
 
0 – no special function<br>
Line 61: Line 56:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
* Each function input may be assigned only 1 digital value.
+
* Each function input may be assigned only 1 digital value  
* Valid in communications phase 2 or higher.
+
* Valid in communications phase 2 or higher
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 12:31, 26 March 2014

Specifies the functionality of the drive digital input 3.
0 – no special function
1 – CW limit switch
2 – CCW limit switch
3 – reserved
4 – reserved
5 – reserved
6 – reserved
7 – reserved
8 – second bipolar torque limit
9 – reserved
10 – home switch
11 – reserved
12 – reserved
13 – reserved
14 – reserved
15 – reserved
16 – probe input (capture)
17 – reserved
18 – open fault relay

Two keyword values are defined:

  • “capturing” (=16)
  • “homing” (=10)

Specifying an invalid value displays the message “Incorrect parameter value”.
Replacing a previous functionality displays the message “Input switch might have been dedicated to another function.”

Syntax

<axis>.In3Mode = <value>

Availability

All versions

Type

Long

Range

0 to 18

Default

Dependent on the drive

Scope

Task or Terminal

Limitations

  • Each function input may be assigned only 1 digital value
  • Valid in communications phase 2 or higher
  • Not supported in EtherCAT system