Difference between revisions of "MC-Basic:axis.CAPTUREPOSITION"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "Read-Only" to "Read only")
m
Line 10: Line 10:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
<font color="red">
 
 
This query encapsulates the IDNVALUE query to get the capture position value. This query returns the position value in user units.
 
This query encapsulates the IDNVALUE query to get the capture position value. This query returns the position value in user units.
</font>
 
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
Line 32: Line 28:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Read only. Can be read in SERCOS communications phase 2 or 4.
+
*Read only
 +
*Can be read in SERCOS communications phase 2 or 4
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 12:18, 26 March 2014

This query encapsulates the IDNVALUE query to get the capture position value. This query returns the position value in user units.

Short form

<axis>.CapPos

Syntax

?<axis>.CapturePosition

Availability

All versions

Type

Double

Range

± MaxDouble

Units

User axis position units, as given by <axis>.POSITIONFACTOR.

Scope

Configuration, Task or Terminal

Limitations

  • Read only
  • Can be read in SERCOS communications phase 2 or 4
  • Not supported in EtherCAT system

Examples

Pos = a1.CapturePosition

See Also