Difference between revisions of "MC-Basic:WRITEIDNVALUEARRAY"
m (Text replace - "''<drive>''" to "''<''drive''>") |
m |
||
Line 17: | Line 17: | ||
<''element''> is optional. In general, only element 7 is used (default). | <''element''> is optional. In general, only element 7 is used (default). | ||
− | |||
− | |||
|TYPE= | |TYPE= | ||
− | + | <''drive''>: Long<br> | |
− | '' | + | <''IDN number''>: Long<br> |
<''value''>: Long Type Array name<br> | <''value''>: Long Type Array name<br> | ||
− | '' | + | <''size''>: Long<br> |
− | '' | + | <''IDN element''>: Long<br> |
<''ring''>: Long<br> | <''ring''>: Long<br> | ||
<''connection''>:Long<br> | <''connection''>:Long<br> | ||
Line 31: | Line 29: | ||
|RANGE= | |RANGE= | ||
− | + | <''drive''>: 1 to 254<br> | |
− | '' | + | <''IDN number''>: 1 to 65535<br> |
− | '' | + | <''IDN element''>: 1 to 7<br> |
− | '' | + | <''size''>: 1 to maximal array element number <br> |
<''ring''>:1<br> | <''ring''>:1<br> | ||
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)<br> | <''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)<br> |
Revision as of 12:01, 26 March 2014
This command writes the data from the preliminary declared Long Type Array to a specified element of an IDN to a specified drive. The number of elements to write is limited by <size> parameter. This function works only for IDNs containing more than one Long Type value in array method .
<element> is optional. In general, only element 7 is used (default).
Short form
WIVALA
Syntax
WRITEIDNVALUEARRAY Drive=<drive address> IDN=<IDN number> Value=<long_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}
Availability
Since Version 4.7.12 for SERCOS III
Type
<drive>: Long
<IDN number>: Long
<value>: Long Type Array name
<size>: Long
<IDN element>: Long
<ring>: Long
<connection>:Long
Range
<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<size>: 1 to maximal array element number
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
Default
<element>: 7
Scope
Configuration, Task or Terminal
Limitations
- Write only.
- Executed only in SERCOS communication phases 2, 3 and 4.
- The IDN must be defined.
- The Long Type Array must be declared preliminary.
- <size> parameter should not be more than maximal number of IDN array elements .
Examples
Example For Bosch Rexroth drive : -->common shared VelFilterType[10] as long -->WriteIdnValueArray Drive=ax1.dadd Idn=0x8000+1122 Value=VelFilterType size=4