Difference between revisions of "MC-Basic:WRITEIDNVALUE"
m (Text replace - "''<drive>''" to "''<''drive''>") |
m |
||
| Line 24: | Line 24: | ||
In this case, the value 3 is written to begin the procedure, and the value 0 is written to cancel the procedure once it has completed. | In this case, the value 3 is written to begin the procedure, and the value 0 is written to cancel the procedure once it has completed. | ||
| − | |||
|TYPE= | |TYPE= | ||
| − | + | <''drive''>: Long<br> | |
| − | '' | + | <''IDN number''>: Long<br> |
<''value''>: Long<br> | <''value''>: Long<br> | ||
| − | '' | + | <''IDN element''>: Long |
<''ring''>: Long | <''ring''>: Long | ||
<''connection''>:Long | <''connection''>:Long | ||
| Line 36: | Line 35: | ||
|RANGE= | |RANGE= | ||
| − | + | <''drive''>: 1 to 254<br> | |
| − | '' | + | <''IDN number''>: 1 to 65535<br> |
| − | '' | + | <''IDN element''>: 1 to 7 <br> |
| − | <''ring''>:1 | + | <''ring''>:1 <br> |
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection) | <''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection) | ||
| Line 53: | Line 52: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
| − | * Write only | + | *Write only |
| − | * Executed only in SERCOS communication phases 2, 3 and 4. | + | *Executed only in SERCOS communication phases 2, 3 and 4. |
| − | * The IDN must be defined | + | *The IDN must be defined |
| + | *Not supported in EtherCAT system | ||
|EXAMPLE= | |EXAMPLE= | ||
Revision as of 11:46, 26 March 2014
This command writes the Long Type value of a specified element of an IDN to a specified drive. It is used when writing to an IDN that takes numeric values.
<element> is optional. In general, only element 7 is used (default).
This command is also used to operate a procedure command. In this case, the value 3 is written to begin the procedure, and the value 0 is written to cancel the procedure once it has completed.
Short form
WIVal
Syntax
WriteIdnValue Drive=<drive address>, Idn=<IDN number>, Value=<value>, {Element=<IDN element number>}
From Since Version 4.7.12 for SERCOS III :
WRITEIDNVALUE Drive=<drive address> IDN=<IDN number> Value=<value {,<value>}> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}
Availability
All versions
Type
<drive>: Long
<IDN number>: Long
<value>: Long
<IDN element>: Long
<ring>: Long
<connection>:Long
Range
<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
Default
<element>: 7
Scope
Configuration, Task or Terminal
Limitations
- Write only
- Executed only in SERCOS communication phases 2, 3 and 4.
- The IDN must be defined
- Not supported in EtherCAT system
Examples
WriteIdnValue Drive=2 Idn=159 Value=10000 'Set PEMAX on drive WIVal Drive = 1 IDN = 99 Value = 3 'Begin Reset Faults procedure From Since Version 4.7.12 for SERCOS III : WriteIdnValue Drive=2 Idn=159 Value=10000 Element= 7 Ring= 1 Connection= 0