Difference between revisions of "MC-Basic:IDNVALUEDOUBLE"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "from Since Version 4.7.12 for SERCOS III" to "Since Version 4.7.12 for SERCOS III")
m
Line 13: Line 13:
 
This function is used to read the double type numeric value of a specified element of an IDN from a specified drive.  
 
This function is used to read the double type numeric value of a specified element of an IDN from a specified drive.  
  
{{Note/Important| '''THIS COMMAND IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
Line 35: Line 34:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Read only. Executed only in SERCOS communication phases 2, 3 and 4.<br>
+
*Read only
 
+
*Executed only in SERCOS communication phases 2, 3 and 4.
The IDN must be defined.
+
*The IDN must be defined
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 11:26, 26 March 2014

This function is used to read the double type numeric value of a specified element of an IDN from a specified drive.

Short form

IvalD

Syntax

IdnValueDouble (<drive address>, <IDN>, <element>, {<ring>}, {<connection>} )

Availability

All versions {<ring>}, {<connection>}) options - Since Version 4.7.12 for SERCOS III

Type

<returned value>: Double

Range

<drive address>: 1 to 254
<IDN>: 1 to 65536
<element>: 1 to 7 <ring>:1 <connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)

Scope

Configuration, Task or Terminal

Limitations

  • Read only
  • Executed only in SERCOS communication phases 2, 3 and 4.
  • The IDN must be defined
  • Not supported in EtherCAT system

Examples

?IDNVALUEDOUBLE(1, 47, 7)

?IDNVALUEDOUBLE (<drive>, <idn>, <element>)

?IDNVALUEDOUBLE (<drive>, <idn>, <element>, <ring>)

?IDNVALUEDOUBLE (<drive>, <idn>, <element>, , <connection>) --> Translator note: Ring number is zero

?IDNVALUEDOUBLE (<drive>, <idn>, <element>, <ring>, <connection>)

See Also