Difference between revisions of "MC-Basic:WRITEIDNVALUEARRAY"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<ring>''" to "<''ring''>")
m (Text replace - "''<connection>''" to "<''connection''>")
Line 27: Line 27:
 
''<IDN element>'': Long<br>
 
''<IDN element>'': Long<br>
 
<''ring''>: Long<br>
 
<''ring''>: Long<br>
''<connection>'':Long<br>
+
<''connection''>:Long<br>
  
  
Line 36: Line 36:
 
''<size>'': 1 to maximal array element number <br>
 
''<size>'': 1 to maximal array element number <br>
 
<''ring''>:1<br>
 
<''ring''>:1<br>
''<connection>'':0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)<br>
+
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)<br>
  
  

Revision as of 10:59, 26 March 2014

This command writes the data from the preliminary declared Long Type Array to a specified element of an IDN to a specified drive. The number of elements to write is limited by <size> parameter. This function works only for IDNs containing more than one Long Type value in array method .


<element> is optional. In general, only element 7 is used (default).

IMPORTANT.svgIMPORTANT
THIS COMMAND IS OBSOLETE

Short form

WIVALA

Syntax

WRITEIDNVALUEARRAY Drive=<drive address> IDN=<IDN number> Value=<long_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}

Availability

Since Version 4.7.12 for SERCOS III

Type

<drive>: Long
<IDN number>: Long
<value>: Long Type Array name
<size>: Long
<IDN element>: Long
<ring>: Long
<connection>:Long

Range

<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<size>: 1 to maximal array element number
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)

Default

<element>: 7

Scope

Configuration, Task or Terminal

Limitations

  • Write only.
  • Executed only in SERCOS communication phases 2, 3 and 4.
  • The IDN must be defined.
  • The Long Type Array must be declared preliminary.
  • <size> parameter should not be more than maximal number of IDN array elements .

Examples


Example For Bosch Rexroth drive :

-->common shared VelFilterType[10] as long 


-->WriteIdnValueArray Drive=ax1.dadd Idn=0x8000+1122 Value=VelFilterType size=4 
 


See Also