Difference between revisions of "MC-Basic:IDNSTRING"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "Read-Only" to "Read only")
m
Line 12: Line 12:
 
This function is used to read the value of a specified element of an IDN from a specified drive. It should be used when reading an IDN that takes string values.
 
This function is used to read the value of a specified element of an IDN from a specified drive. It should be used when reading an IDN that takes string values.
  
{{Note/Important| '''THIS COMMAND IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
Line 32: Line 31:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Read only. Executed only in SERCOS communication phases 2, 3 and 4.
+
*Read only  
 +
*Executed only in SERCOS communication phases 2, 3 and 4
 +
*Not supported in EtherCAT system
 +
 
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 10:54, 26 March 2014

This function is used to read the value of a specified element of an IDN from a specified drive. It should be used when reading an IDN that takes string values.

Short form

Istr

Syntax

?IdnString (<drive address>, <IDN>, <element>)

Availability

All versions

Range

<drive address>: 1 to 254
<IDN>: 1 to 65535
<element>: 1 to 7

Scope

Configuration, Task or Terminal

Limitations

  • Read only
  • Executed only in SERCOS communication phases 2, 3 and 4
  • Not supported in EtherCAT system

Examples

?IdnString(1, 95, 7)                                     ‘Get diagnostic message from drive

See Also