Difference between revisions of "MC-Basic:robot.DECELERATIONSTOPROT"
m (Text replace - "R/W" to "Read/Write") |
m (Text replace - "Versions 4.2.x and higher" to "Since Version 4.2.x") |
||
| Line 7: | Line 7: | ||
|AVAILABILITY= | |AVAILABILITY= | ||
| − | + | Since Version 4.2.x | |
|DESCRIPTION= | |DESCRIPTION= | ||
Revision as of 16:53, 20 March 2014
DecStopRot present the rotation stopping deceleration in case of stop command from type DecStopOnPath. This value is used when stop interrupts to a Robot movement from type Circle or MoveS..
Short form
<ROBOT>.DecStopRot
Syntax
<ROBOT>.DECELERATIONSTOPROT = <value>
Availability
Since Version 4.2.x
Type
Double
Range
0.01 to Max Double
Units
deg/sec2
Default
4e4 * pi/180
Scope
Terminal or task
Limitations
Read/Write . Modal Only. Robot property only.
Examples
<ROBOT>.DECELERATIONSTOPROT = 5000