Difference between revisions of "AXY:MC-Basic:axis.TIMEACCMIN"
m (Text replace - "<AXIS>" to "<''axis''>") |
|||
| Line 1: | Line 1: | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
| − | < | + | <''axis''>.TAccMin |
|SYNTAX= | |SYNTAX= | ||
| − | < | + | <''axis''>.TAccMin=<''numeric expression''> |
|AVAILABILITY= | |AVAILABILITY= | ||
Revision as of 11:49, 19 March 2014
Defines minimum acceleration time, if set to 0 the whole feature is switched off.
Short form
<axis>.TAccMin
Syntax
<axis>.TAccMin=<numeric expression>
Availability
Versions AMCS 0.4.4.x and higher
Type
integer
Range
0-maxlong
Units
milliseconds
Default
0 – not active
Scope
Task, Terminal
Limitations
Modal/Nodal Read/Write
Examples
A1.timeaccmin = 500
A1.timedecmin = 1000
A1. timeofshortmotions = 200