The target position is specified within each motion command. As an individual property it is read-only.
+
* The target position is specified within each motion command.  
 +
* Read only, as an individual property.
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 09:55, 19 March 2014

This property returns the axis target position. This target position is set within the MOVE or CIRCLE motion commands.

Short form

<axis>.PFinal

Syntax

?<axis>.PositionFinal

Availability

All versions

Type

Double

Range

± Max Double

Units

User axis position units, as given by <axis>.POSITIONFACTOR.

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • The target position is specified within each motion command.
  • Read only, as an individual property.

Examples

?X.Pfinal

See Also