Difference between revisions of "MC-Basic:axis.POSITIONEXTROLLOVERENABLE"

From SoftMC-Wiki
Jump to: navigation, search
Line 15: Line 15:
 
This property is used to enable or disable position rollover on PEXT. When position external rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.<br>
 
This property is used to enable or disable position rollover on PEXT. When position external rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.<br>
 
</font>
 
</font>
0 (OFF - Rollover is disabled)<br>
+
0 (OFF) - Rollover is disabled <br>
1 (ON - Rollover is enabled)
+
1 (ON) - Rollover is enabled
  
 
|TYPE=
 
|TYPE=

Revision as of 09:38, 19 March 2014

This property is used to enable or disable position rollover on PEXT. When position external rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.
0 (OFF) - Rollover is disabled
1 (ON) - Rollover is enabled

Syntax

<axis>.PositionExtRollOverEnable= <option>

?<axis>.PositionRollOverEnable

Availability

All versions

Type

Long

Range

0 (OFF)
1 (ON)

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • The position rollover setting may be changed only when the axis is disabled.
  • To set the value within a task, the axis must be attached to that task (using the ATTACH command).

Examples

A1.PositionExtRollover  = 1000

Set rollover value

A1.PositionExtRollOverEnable = On

Enable position rollover

See Also