Difference between revisions of "MC-Basic:axis.POSITIONEXTROLLOVERENABLE"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<axis>''" to "<''axis''>")
Line 12: Line 12:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
This property is used to enable or disable position rollover on PEXT. When position EXT rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.<br>
+
<font color="red">
       0 (OFF - Rollover is disabled)<br>
+
This property is used to enable or disable position rollover on PEXT. When position external rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.<br>
       1 (ON - Rollover is enabled)
+
</font>
 +
0 (OFF - Rollover is disabled)<br>
 +
1 (ON - Rollover is enabled)
  
 
|TYPE=
 
|TYPE=
Line 20: Line 22:
  
 
|RANGE=
 
|RANGE=
0 (OFF), 1 (ON)
+
0 (OFF)<br>
 +
1 (ON)
  
 
|UNITS=
 
|UNITS=
Line 32: Line 35:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
The position rollover setting may be changed only when the axis is disabled<br>
+
* The position rollover setting may be changed only when the axis is disabled.
 
+
* To set the value within a task, the axis must be attached to that task (using the ATTACH command).
To set the value within a task, the axis must be attached to that task (using the ATTACH command).
 
  
 
|EXAMPLE=
 
|EXAMPLE=
A1.PositionExtRollover  = 1000                   ‘Set rollover value<br>
+
A1.PositionExtRollover  = 1000
 +
::::Set rollover value<br>
  
A1.PositionExtRollOverEnable = On                        ‘Enable position rollover
+
A1.PositionExtRollOverEnable = On
 +
::::Enable position rollover
  
 
|SEE ALSO=
 
|SEE ALSO=

Revision as of 09:38, 19 March 2014

This property is used to enable or disable position rollover on PEXT. When position external rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.
0 (OFF - Rollover is disabled)
1 (ON - Rollover is enabled)

Syntax

<axis>.PositionExtRollOverEnable= <option>

?<axis>.PositionRollOverEnable

Availability

All versions

Type

Long

Range

0 (OFF)
1 (ON)

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • The position rollover setting may be changed only when the axis is disabled.
  • To set the value within a task, the axis must be attached to that task (using the ATTACH command).

Examples

A1.PositionExtRollover  = 1000

Set rollover value

A1.PositionExtRollOverEnable = On

Enable position rollover

See Also