Revision as of 07:09, 19 March 2014

DecStopTran present the translation stopping deceleration in case of stop command from type DecStopOnPath. This value is used when stop interrupts to a Robot movement from type Circle or MoveS.

Short form

<ROBOT>.DecStopTran

Syntax

<ROBOT>.DECELERATIONSTOPTRANS = <value>

Availability

Versions 4.2.x and higher

Versions 4.2.x and higher

Type

Double

Range

0.01 to Max Double

Units

mm/sec2

Default

1e5

Scope

Terminal or task

Limitations

Read/Write . Modal Only. Robot property only.

Examples

Scara.DecStopTran = 1000

See Also