Revision as of 13:51, 18 March 2014

This query returns the peak realtime load on the CPU. This is the maximum value of the realtime load measured during a 0.5 seconds interval.

Short form

?Sys.PLoad

?System.PLoad

Syntax

?Sys.PeakLoad

?System.PeakLoad

Availability

All versions

Type

Long.

Range

0 to 100

Units

Percent

Scope

Task or Terminal

Limitations

Read only. Cannot be used in an event condition.

Examples

?System.Pload                                             ‘returns 45