Difference between revisions of "MC-Basic:axis.MASTERSYNC"
m (Text replace - "''<axis>''" to "<''axis''>") |
|||
Line 10: | Line 10: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | MASTERSYNC is a read-only axis property indicating whether the speed of the slave is synchronized to the master. This flag is cleared when gearing is enabled and set when synchronization is achieved. Synchronization is achieved when the slave velocity is equal to the master velocity for the first time. | + | MASTERSYNC is a read-only axis property indicating whether the speed of the slave is synchronized to the master. This flag is cleared when gearing is enabled, and set when synchronization is achieved. Synchronization is achieved when the slave velocity is equal to the master velocity for the first time. |
|TYPE= | |TYPE= | ||
Line 28: | Line 28: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | Read | + | Read only |
|EXAMPLE= | |EXAMPLE= | ||
If X_Axis.MasterSync Then<br> | If X_Axis.MasterSync Then<br> | ||
− | + | ::Move X_axis x_axis.SlaveLag Absolute = 0 | |
|SEE ALSO= | |SEE ALSO= |
Revision as of 13:23, 18 March 2014
MASTERSYNC is a read-only axis property indicating whether the speed of the slave is synchronized to the master. This flag is cleared when gearing is enabled, and set when synchronization is achieved. Synchronization is achieved when the slave velocity is equal to the master velocity for the first time.
Short form
<axis>.MSYN
Syntax
?<axis>.MasterSync
Availability
All versions
Type
Long
Range
0 or 1
Default
0
Scope
Configuration, Task or Terminal
Limitations
Read only
Examples
If X_Axis.MasterSync Then
- Move X_axis x_axis.SlaveLag Absolute = 0