Difference between revisions of "MC-Basic:axis.HOMEOFFSET"
Line 10: | Line 10: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
+ | |||
+ | {{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | ||
+ | |||
+ | |||
+ | |||
This property determines the motor position feedback relative to the machine's zero point. | This property determines the motor position feedback relative to the machine's zero point. | ||
− | |||
|TYPE= | |TYPE= | ||
Double | Double |
Revision as of 11:06, 18 March 2014
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
This property determines the motor position feedback relative to the machine's zero point.
Short form
<axis>.Hoff
Syntax
<axis>.HomeOffset = <value>
Availability
All versions
Type
Double
Range
Limited by the drive.
Units
User position units
Default
Dependent on the drive
Scope
Terminal and Task
Limitations
- Valid in communications phase 2 or higher.
- To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
?a1.hoff
a1.hoff = -50