Difference between revisions of "MC-Basic:axis.HOMEOFFSET"
m (Text replace - "''<value>''" to "<''value''>") |
|||
Line 29: | Line 29: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | Valid in communications phase 2 or higher. | + | * Valid in communications phase 2 or higher. |
− | + | * To set the value within a task, the axis must be attached to that task (using the ATTACH command). | |
− | To set the value within a task, the axis must be attached to that task (using the ATTACH command). | ||
|EXAMPLE= | |EXAMPLE= |
Revision as of 10:54, 18 March 2014
This property determines the motor position feedback relative to the machine's zero point.
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Short form
<axis>.Hoff
Syntax
<axis>.HomeOffset = <value>
Availability
All versions
Type
Double
Range
Limited by the drive.
Units
User position units
Default
Dependent on the drive
Scope
Terminal and Task
Limitations
- Valid in communications phase 2 or higher.
- To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
?a1.hoff
a1.hoff = -50