Difference between revisions of "AXY:MC-Basic:axis.ENABLE"
m (Text replace - "''<axis>''" to "<''axis''>") |
|||
Line 4: | Line 4: | ||
|SYNTAX= | |SYNTAX= | ||
− | <''axis''>.Enable = <value><br> | + | <''axis''>.Enable = <''value''><br> |
?<''axis''>.Enable | ?<''axis''>.Enable | ||
Line 17: | Line 17: | ||
0 (OFF) - Drive disable<br> | 0 (OFF) - Drive disable<br> | ||
− | + | 1 (ON) - Drive enable | |
|TYPE= | |TYPE= |
Revision as of 10:04, 18 March 2014
This property enables or disables the drive. The property encapsulates operation of drive status bit 15, and causes an active disable of the drive when set to 0. The MC interpreter is held until the requested state is actually achieved on the drive.
When the drive is disabled, the motion controller of that axis is in a following mode, so the command follows the feedback. A message is generated by the MC that the axis is now in following mode. Motion commands are not allowed when the drive is disabled.
0 (OFF) - Drive disable
1 (ON) - Drive enable
Short form
<axis>.En
Syntax
<axis>.Enable = <value>
?<axis>.Enable
Availability
All versions
Type
Long
Range
0 or 1
Default
0 (at power on)
Scope
Configuration, Task or Terminal
Limitations
Real axes are enabled and disabled only in SERCOS communication phase 4. Simulated axes are enabled and disabled in SERCOS communication phases 4 and 0. The SYSTEM.ENABLE flag must be ON in order for a drive to be enabled.
Examples
a1.enable = 1