Difference between revisions of "AXY:MC-Basic:axis.BLENDINGFACTOR"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<value>''" to "<''value''>")
m (Text replace - "<Axis>" to "<''axis''>")
Line 4: Line 4:
  
 
|SYNTAX=
 
|SYNTAX=
?<Axis>.BlendingFactor<br>
+
?<''axis''>.BlendingFactor<br>
  
<Axis>. BlendingFactor  = <''value''>
+
<''axis''>. BlendingFactor  = <''value''>
  
 
|AVAILABILITY=
 
|AVAILABILITY=

Revision as of 16:02, 17 March 2014

Percentage of the movement’s length that will be not blended with the next movement.

0% – blending of second movement started from the beginning of the first one .

100% – blending of second movement started from the end of the first one (NO BLENDING) .

Syntax

?<axis>.BlendingFactor

<axis>. BlendingFactor  = <value>

Availability

Versions AMCS 0.3.6.20 and higher

Type

Double

Range

0 to 100

Units

Percents of the segments length

Default

100 (no blending)

Scope

Task or Terminal

Limitations

Mixed profiler types are not valid , Modal/Nodal

Examples

Ax1. BlendingFactor= 10

?Ax1. BlendingFactor

See Also