Revision as of 15:38, 17 March 2014

Specifies the required jog velocity. This property has no default value and you must specify its value each time a JOG command is issued. The sign of velocity defines the direction of movement.

Short form

<axis>.Vjog

Syntax

<axis>.VelocityJog = <value>

Availability

All versions

Type

Double

Range

± VelocityMax

Units

User velocity units, as given by <axis>.VELOCITYFACTOR

Scope

Task or Terminal

Limitations

The value is only set within a JOG command. Read only when not specified with the JOG command.

Examples

Jog Xaxis 200 TimeJog=20

?Xaxis.VelocityJog

See Also