Revision as of 15:36, 17 March 2014

This property returns the axis target position. This target position is set within the MOVE or CIRCLE motion commands.

Short form

<axis>.PFinal

Syntax

?<axis>.PositionFinal

Availability

All versions

Type

Double

Range

± Max Double

Units

User axis position units, as given by <axis>.POSITIONFACTOR.

Default

0

Scope

Configuration, Task or Terminal

Limitations

The target position is specified within each motion command. As an individual property it is read-only.

Examples

?X.Pfinal