Difference between revisions of "MC-Basic:WRITEIDNVALUEDOUBLE"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<value>''" to "<''value''>")
m (Text replace - "''<element>''" to "<''element''>")
Line 15: Line 15:
 
It is used when writing to an IDN that takes Double Type numeric values.  
 
It is used when writing to an IDN that takes Double Type numeric values.  
  
''<element>'' is optional. In general, only element 7 is used (default).  
+
<''element''> is optional. In general, only element 7 is used (default).  
  
 
{{Note/Important| '''THIS COMMAND IS OBSOLETE'''}}
 
{{Note/Important| '''THIS COMMAND IS OBSOLETE'''}}
Line 41: Line 41:
  
 
|DEFAULT=
 
|DEFAULT=
''<element>'': 7
+
<''element''>: 7
  
 
|SCOPE=
 
|SCOPE=

Revision as of 14:51, 17 March 2014

This command writes the Double Type Value of a specified element of an IDN to a specified drive. It is used when writing to an IDN that takes Double Type numeric values.

<element> is optional. In general, only element 7 is used (default).

IMPORTANT.svgIMPORTANT
THIS COMMAND IS OBSOLETE

Short form

WIVALD

Syntax

WRITEIDNVALUEDOUBLE Drive=<drive address> IDN=<IDN number> Value=<value {,<value>}> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}

Availability

AMCS 0.4.7.12 for SERCOS III

Type

<drive>: Long
<IDN number>: Long
<value>: Double
<IDN element>: Long <ring>: Long <connection>:Long

Range

<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7 <ring>:1 <connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)

Units

<Value> : Double

Default

<element>: 7

Scope

Configuration, Task or Terminal

Limitations

  • Write-Only.
  • Executed only in SERCOS communication phases 2, 3 and 4.
  • The IDN must be defined.

Examples

WriteIdnValueDouble Drive=2 Idn=<IDN number> Value=10000       
 

for  SERCOS III :

WriteIdnValue Drive=2 Idn=<IDN number> Value=10000 Element= 7 Ring= 1 Connection= 0


See Also