Difference between revisions of "MC-Basic:WRITEIDNVALUEARRAY"
m (Text replace - "''<value>''" to "<''value''>") |
m (Text replace - "''<element>''" to "<''element''>") |
||
Line 16: | Line 16: | ||
− | '' | + | <''element''> is optional. In general, only element 7 is used (default). |
{{Note/Important| '''THIS COMMAND IS OBSOLETE'''}} | {{Note/Important| '''THIS COMMAND IS OBSOLETE'''}} | ||
Line 43: | Line 43: | ||
|DEFAULT= | |DEFAULT= | ||
− | '' | + | <''element''>: 7 |
|SCOPE= | |SCOPE= |
Revision as of 14:50, 17 March 2014
This command writes the data from the preliminary declared Long Type Array to a specified element of an IDN to a specified drive. The number of elements to write is limited by <size> parameter. This function works only for IDNs containing more than one Long Type value in array method .
<element> is optional. In general, only element 7 is used (default).
IMPORTANT | |
THIS COMMAND IS OBSOLETE |
Short form
WIVALA
Syntax
WRITEIDNVALUEARRAY Drive=<drive address> IDN=<IDN number> Value=<long_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}
Availability
AMCS 0.4.7.12 for SERCOS III
Type
<drive>: Long
<IDN number>: Long
<value>: Long Type Array name
<size>: Long
<IDN element>: Long
<ring>: Long
<connection>:Long
Range
<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<size>: 1 to maximal array element number
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
Default
<element>: 7
Scope
Configuration, Task or Terminal
Limitations
- Write-Only.
- Executed only in SERCOS communication phases 2, 3 and 4.
- The IDN must be defined.
- The Long Type Array must be declared preliminary.
- <size> parameter should not be more than maximal number of IDN array elements .
Examples
Example For Bosch Rexroth drive : -->common shared VelFilterType[10] as long -->WriteIdnValueArray Drive=ax1.dadd Idn=0x8000+1122 Value=VelFilterType size=4