Set or query the rotary axis rollover value.. When an axis has the POSITIONEXTROLLOVERENABLE flag set (ON), it means that POSITION EXTERNAL of this axis is rotary (i.e., the position exteranl coordinate of the axis are periodical). POSITIONEXTROLLOVER defines the period (the length one revolution in user units) of PEXT of the the axis.
The effect of this property is such that the position external (as seen by the user), is a modulus of the POSITIONEXTROLLOVER.
Syntax
<axis>.PositionExtRollover = <value>
?<axis>.PositionExtRollover
Availability
All versions
Type
Double
Range
Greater than zero
Default
360
Scope
Configuration, Task or Terminal
Limitations
The PositionExtRollover value may be changed only when the axis is disabled
To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples