Difference between revisions of "AXY:MC-Basic:group.VELOCITYFACTOR"
m (note template) |
m (Text replace - "''<expression>''" to "<''expression''>") |
||
| Line 4: | Line 4: | ||
|SYNTAX= | |SYNTAX= | ||
| − | ''<GROUP>.''VelocityFactor = '' | + | ''<GROUP>.''VelocityFactor = <''expression''><br> |
?''<GROUP>.''VelocityFactor | ?''<GROUP>.''VelocityFactor | ||
Revision as of 08:29, 17 March 2014
This property specifies the conversion factor between the user velocity units and the internal units [counts per msec].
| NOTE | |
| In using VELOCITYFACTOR for a group, the position units are taken from the POSITIONFACTOR of the axes within the group. The position units must not be specified in the group’s VELOCITYFACTOR. |
Short form
<GROUP>.Vfac
Syntax
<GROUP>.VelocityFactor = <expression>
?<GROUP>.VelocityFactor
Availability
All versions
Type
Double
Range
Greater than zero
Default
1/60000 (for working in units of position units per minute)
Scope
Configuration, Task or Terminal
Limitations
Cannot be changed while axis is enabled or while axis is set up as a master axis.
To set the value within a task, the group must be attached to that task (using the ATTACH command).
Examples
G1.Vfac = 1 / 60000 ‘work in per minute
G1.Vfac = 1 / 1000 ‘work in per second