Difference between revisions of "AXY:MC-Basic:axis.STOPTYPE"
m (Text replace - "''<axis>''" to "<''axis''>") |
m (Text replace - "''<expression>''" to "<''expression''>") |
||
Line 4: | Line 4: | ||
|SYNTAX= | |SYNTAX= | ||
− | <''axis''>.StopType = '' | + | <''axis''>.StopType = <''expression''><br> |
? <''axis''>.StopType | ? <''axis''>.StopType |
Revision as of 08:24, 17 March 2014
This property defines how the motion is stopped in response to the STOP command. The STOP type is used within a STOP command to override the permanent value for only that STOP command.
1 (IMMEDIATE): Immediate stop, using maximum deceleration.
2 (ONPATH): Immediate stop, using maximum deceleration ,on the path of the motion. This is useful for stopping group motion so all axes remain on the original path of travel during the stop. For a single axis, the IMMEDIATE and ONPATH stop types are the same.
3 (ENDMOTION): Stop at the end of the current motion command.
4 (ABORT): Stop the current motion immediate but do not wait for proceed to start next motion. – Only the accepted motion commands are stopped, the commands coming after this stoptype will be executed regularly.
5 (DecStopOnPath ) - the stopping procedure is started immediately according to DecStop value .As this parameter as modal so its value must be updated before executing the motion command.
Syntax
<axis>.StopType = <expression>
? <axis>.StopType
Availability
All versions
Type
Long
Range
1 to 5
Default
1
Scope
Configuration, Task or Terminal
Examples
X_axis.StopType = 2
Stop X_axis StopType=3