Difference between revisions of "MC-Basic:axis.POSITIONEXTERNALFACTOR"
m (Text replace - "''<axis>''" to "<''axis''>") |
m (Text replace - "''<expression>''" to "<''expression''>") |
||
Line 4: | Line 4: | ||
|SYNTAX= | |SYNTAX= | ||
− | <''axis''>.PositionExternalFactor = '' | + | <''axis''>.PositionExternalFactor = <''expression''><br> |
?<''axis''>.PositionExternalFactor | ?<''axis''>.PositionExternalFactor | ||
Revision as of 08:23, 17 March 2014
The position factor of the external feedback is used to convert that value from counts into physical units.
Short form
<axis>.PExtfac
Syntax
<axis>.PositionExternalFactor = <expression>
?<axis>.PositionExternalFactor
Availability
All versions
Type
Double
Range
Greater than 0
Default
1
Scope
Configuration, Task or Terminal
Limitations
Drive must be disabled.
To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
A1.PositionExternalFactor = 2048