Line 4: Line 4:
  
 
|SYNTAX=
 
|SYNTAX=
''<axis>''.PositionExtRollOverEnable= ''<option>''<br>
+
<''axis''>.PositionExtRollOverEnable= ''<option>''<br>
  
?''<axis>''.PositionRollOverEnable
+
?<''axis''>.PositionRollOverEnable
  
 
|AVAILABILITY=
 
|AVAILABILITY=

Revision as of 17:46, 16 March 2014

This property is used to enable or disable position rollover on PEXT. When position EXT rollover is enabled, the axis POSITIONEXTROLLOVER property has relevance and the PEXT value is the modulus of the POSITIONEXTROLLOVER property value.
       0 (OFF - Rollover is disabled)
       1 (ON - Rollover is enabled)

Syntax

<axis>.PositionExtRollOverEnable= <option>

?<axis>.PositionRollOverEnable

Availability

All versions

Type

Long

Range

0 (OFF), 1 (ON)

Default

0

Scope

Configuration, Task or Terminal

Limitations

The position rollover setting may be changed only when the axis is disabled

To set the value within a task, the axis must be attached to that task (using the ATTACH command).

Examples

A1.PositionExtRollover  = 1000                   ‘Set rollover value

A1.PositionExtRollOverEnable = On                        ‘Enable position rollover