Difference between revisions of "MC-Basic:axis.IN2MODE"
Line 66: | Line 66: | ||
* [[Axystems:MC-Basic:axis.IN2|axis.IN2]] | * [[Axystems:MC-Basic:axis.IN2|axis.IN2]] | ||
− | [Category:Axystems:Obsolete|axis.IN2MODE]] | + | [[Category:Axystems:Obsolete|axis.IN2MODE]] |
}} | }} |
Revision as of 14:45, 11 March 2014
Specifies the functionality of the drive digital input 2.
0 – no special function
1 – CW limit switch
2 – CCW limit switch
3 – reserved
4 – reserved
5 – reserved
6 – reserved
7 – reserved
8 – second bipolar torque limit
9 – reserved
10 – home switch
11 – reserved
12 – reserved
13 – reserved
14 – reserved
15 – reserved
16 – probe input (capture)
17 – reserved
18 – open fault relay
Two keyword values are defined:
“capturing” (=16)
“homing” (=10)
Specifying an invalid value displays the message, “Incorrect parameter value”. Replacing a previous functionality displays the message, “Input switch might have been dedicated to another function.”
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Syntax
<axis>.In2Mode = <value>
Availability
All versions
Type
Long
Range
0 to 18
Default
Dependent on the drive
Scope
Task or Terminal
Limitations
Each function input may be assigned only one digital value. Valid in communications phase 2 or higher.
Examples
?a1.In2Mode
a1.In2Mode = homing