Difference between revisions of "MC-Basic:axis.CAPTUREPOSITION"
m (1 revision) |
|||
Line 11: | Line 11: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
This query encapsulates the IDNVALUE query to get the capture position value. This query returns the position value in user units.. | This query encapsulates the IDNVALUE query to get the capture position value. This query returns the position value in user units.. | ||
+ | |||
+ | {{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | ||
|TYPE= | |TYPE= | ||
Line 40: | Line 42: | ||
* [[Axystems:MC-Basic:IDNVALUE|IDNVALUE]] | * [[Axystems:MC-Basic:IDNVALUE|IDNVALUE]] | ||
− | + | [[Category:Axystems:Obsolete|axis.CAPTUREPOSITION]] | |
}} | }} |
Revision as of 14:25, 11 March 2014
This query encapsulates the IDNVALUE query to get the capture position value. This query returns the position value in user units..
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Short form
<axis>.CapPos
Syntax
?<axis>.CapturePosition
Availability
All versions
Type
Double
Range
+/- MaxDouble
Units
User axis position units, as given by <axis>.POSITIONFACTOR.
Scope
Configuration, Task or Terminal
Limitations
Read-Only. Can be read in SERCOS communications phase 2 or 4.
Examples
Pos = a1.CapturePosition