Difference between revisions of "MC-Basic:axis.TIMEOFSHORTMOTIONS"

From SoftMC-Wiki
Jump to: navigation, search
Line 10: Line 10:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
Defines lower threshold below which TACCMIN and TDECMIN are not affection the motion anymore.
+
Defines lower threshold below which TACCMIN and TDECMIN are not affection the motion anymore. If actual values of acceleration (or deceleration) time is below this limit the whole excitation-limiting algorithm (TACCMIN & TDECMIN) is switched off.  
  
{{Note|Settingone of TACCMIN, TDECMIN or TSHORT to 0, disables the whole timing feature altogether}}
+
{{Note/Caution|Value of TSHORT is compared to acceleration/deceleration time only and not to the whole duration of movement. Therefore long movements with long cruise-velocity phase and short acceleration/deceleration times could trigger the switching-off the excitation-limiting algorithm. Use small values (1-4ms) for best results.}}
 +
 
 +
{{Note|Setting one of TACCMIN, TDECMIN or TSHORT to 0, disables the whole timing feature (excitation-limiting algorithm) altogether}}
  
 
|TYPE=
 
|TYPE=

Revision as of 13:44, 10 February 2014

Defines lower threshold below which TACCMIN and TDECMIN are not affection the motion anymore. If actual values of acceleration (or deceleration) time is below this limit the whole excitation-limiting algorithm (TACCMIN & TDECMIN) is switched off.

CAUTION.svgCAUTION
Value of TSHORT is compared to acceleration/deceleration time only and not to the whole duration of movement. Therefore long movements with long cruise-velocity phase and short acceleration/deceleration times could trigger the switching-off the excitation-limiting algorithm. Use small values (1-4ms) for best results.
NOTE-Info.svgNOTE
Setting one of TACCMIN, TDECMIN or TSHORT to 0, disables the whole timing feature (excitation-limiting algorithm) altogether

Short form

<AXIS>.TSHORT

Syntax

<AXIS>.TSHORT=<numeric expression>

Availability

Versions AMCS 0.4.4.x and higher

Type

long

Range

0-maxlong

Units

milliseconds

Default

0 –not active

Scope

Task, Terminal

Limitations

Modal/Nodal Read/Write

Examples

A1.timeaccmin = 500

A1.timedecmin = 1000

A1.timeofshortmotions = 200