Defines jerk value of the translational moving frame componenet.Used during synchronization process for target prediction (from the time tracking is started (e.g. Slave=5) until it is synchronized with moving frame <robot>.IMFS = 1)

Syntax

<ROBOT>.JerkSyncTran = <numeric expression>

Availability

Version 0.4.0.22 and higher

Type

Double

Range

0 to MaxDouble

Units

mm/sec³

Default

100000

Scope

Configuration, Task or Terminal

Limitations

R/W, Modal Only

Examples

Scara.JerkSyncTran = 500