The complete system of the sync-list motion profiles will be executed together just be scaling each of them by the factor of:<math>\frac{L_i}{\sqrt{\sum L_i ^2}}</math> | The complete system of the sync-list motion profiles will be executed together just be scaling each of them by the factor of:<math>\frac{L_i}{\sqrt{\sum L_i ^2}}</math> | ||
+ | |||
+ | |||
+ | |||
+ | <gallery> | ||
+ | Image:AXY;MasterProfiler.png|''Master profiler'' | ||
+ | Image:AXY;MasterProfilerAcceleration.png|''Master profiler accleration'' | ||
+ | </gallery> | ||
+ | |||
+ | |||
+ | [[Image:AXY;SyncListProfiles.png | Sync List profiles]] |
Revision as of 09:22, 31 January 2012
Element Synchronization Design
Common algorithms to both SyncStart and SyncAll:
Pre-Calculation
Is done in MotionManager task, initiated by message sent from SyncStart/All commands:
In case of SyncStart we sperately execute MotCalc on every element from the sync-list:
FOR element FROM sync-list element->MotCalc() NEXT
In case of SyncAll it is little bit more complicated, every element is pre-calculated in order to estimate it's own max profile values:
FOR element FROM sync-list element->MotCalc() ==> Li , Vi , Ai , Di , Jai , Jdi NEXT
And then generate a master profile with the following parameters:
The master profile data-structure will be copied to the profile-data-structure of all other elements.
Master profile:
, , , , ,
where
The master profile data-structure will be copied to the profile-data-structure of all other elements.
The complete system of the sync-list motion profiles will be executed together just be scaling each of them by the factor of: