Difference between revisions of "OperationalModes"
(→See also:) |
|||
Line 1: | Line 1: | ||
− | |||
− | |||
==Enabling user working in different operation modes of the drive== | ==Enabling user working in different operation modes of the drive== | ||
Revision as of 11:55, 16 January 2012
Contents
Enabling user working in different operation modes of the drive
User selects the operation-mode using the OpMode command.
<axis>.OpMode = {POSITIONMODE|VELOCITYMODE|TORQUEMODE}
Command will change the drive (and axis!) opmode to the given value using the opmode bits of the SERCOS drive status word.
- Default state is POSITIONMODE (as today). All the standard deviation thresholds are checked: pe < pemax,vfb < vospd, te < terrmax, acmd < amax and tcmd < tmax.
- In VELOCITYMODE axis will NOT check position-error, but will check: vfb < vospd, te < terrmax, acmd < amax and tcmd < tmax.
- In TORQUEMODE axis will NOT check position-error or acceleration max, but will check: vfb < vospd, te < terrmax and tcmd < tmax.
Torque Interpolation
New torque interpolation command will be implemented:
TORQUE <axis> tfinal
- This command interpolate the tcmd from its initial value to the given tfinal according to the profile parameters defined.
- In case TORQUE command is issued in POSITIONMODE or in VELOCITYMODE a note will be thrown and the TORQUE command will continue as usual interpolating TCMD (with probably no effects - as the drive is not in TORQUEMODE).
Stopping
- STOP command in TORQUEMODE mode will forcibly switch drive opmode to VELOCTYMODE producing the deceleration profile from the current VFB value t zero. The same behavior will be implemend for both user-entred stop command and the system-generated stop commands like: velocity-over speed error, tcmd > tmax, te>temax.
- New command HOLD <Axis> will cause axis to stop interpolating torque. New property <axis>.HoldType will give the user option to select between keeping the stopped TCMD value or reducing it to zero. In bot cases the original TORQUEMODE will be not changed.
HOLD <axis> {HoldType = <value>}
Mode: | |
|
Position | |
HoldType value ignored! |
Velocity | |
HoldType value ignored! |
Torque | first switches into velocityMode with vcmd = vfb then executes motion profile from the vcmd to 0 according the given StopType |
HoldTyepe = 0 immediately(no profile) brakes TORQUE command and sets TCMD = 0 HoldTyepe = 1 immediately(no profile) brakes TORQUE command and keeps tha last value of TCMD |
Limitations and side effects
NOTE | |
Opmode changes are allowed in disabled drive state only. |
NOTE | |
If an axis belongs to a group it's opmode can not be changed separately.This means:
|
NOTE | |
MOVE <axis> and JOG <axis> commands are producing PCMD,VCMDand TADDCMD (if DynamicModel is turned on). The TCMD value during these types of motion remains unchanged. |
NOTE | |
TORQUE <axis> command is affecting PCMD, VCMD, TADDCMD values of the axis (their values are kept unchanged).Only the TCMD is interpolated. |
NOTE | |
We assume dirves adds the TCMD(IDN80) and TADDCMD(IDN81) in all OPMODEs. In case it is not so <axis>.SumTorque=1 will cause the value of TADDCMD to be added to TCMD: |
NOTE | |
TORQUEMODE of an axis is not influencing camming/gearing operation. The interpolated torque values of a master axis will be NOT transferred to slave axes. |
See also: