Difference between revisions of "MC-Basic:SineWave"
m (draft) |
(draft) |
||
Line 8: | Line 8: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | + | Motion command which performs endless sine-wave motion on the given axis or group. | |
− | |||
;''<amplitude>'' | ;''<amplitude>'' | ||
: Peak-to-Peak amplitude between the current position and the given position. | : Peak-to-Peak amplitude between the current position and the given position. | ||
+ | |||
+ | * Starts endless sine-wave motion. The [[Axystems:MC-Basic:STOP|Stop]] command is used to end the motion. | ||
+ | * Group motion is performed on axes level, e.g. no coupling is applied. | ||
+ | * Frequency is set by the SineWaveFreq property. The maximal frequency is limited by vmax and amax. | ||
|TYPE= | |TYPE= | ||
Line 39: | Line 42: | ||
|SEE ALSO= | |SEE ALSO= | ||
+ | * [[AXY:MC-Basic:group.SineWaveFreq|group.SineWaveFreq]] | ||
+ | * [[AXY:MC-Basic:axis.SineWaveFreq|axis.SineWaveFreq]] | ||
}} | }} | ||
+ | |||
+ | [[Category:Axystems:Motion Dynamics]] |
Revision as of 07:43, 10 November 2011
Motion command which performs endless sine-wave motion on the given axis or group.
- <amplitude>
- Peak-to-Peak amplitude between the current position and the given position.
- Starts endless sine-wave motion. The Stop command is used to end the motion.
- Group motion is performed on axes level, e.g. no coupling is applied.
- Frequency is set by the SineWaveFreq property. The maximal frequency is limited by vmax and amax.
Syntax
SineWave <axis>|<group> <amplitude>
Availability
FW 4.7.14+x
Type
- <amplitude>
- double for axes
- vector of double for groups
Scope
Task or Terminal
Limitations
- No joints are allowed, only axes and groups.
Examples
SineWave ax2 300 SineWaveFreq=4 SineWave grp2 {100, 75} SineWaveFreq={3, 5}