Difference between revisions of "MC-Basic:axis.CountExtRollOver"

From SoftMC-Wiki
Jump to: navigation, search
(Ver number)
(Setting zero , drive disable)
Line 5: Line 5:
 
|AVAILABILITY=From ver 4.7.14
 
|AVAILABILITY=From ver 4.7.14
 
|DESCRIPTION=There are drives as  BOSCH drives where there are two standard IDN defining minimum and maximum
 
|DESCRIPTION=There are drives as  BOSCH drives where there are two standard IDN defining minimum and maximum
values of counts rollover.<br/>
+
values of counts rollover.<br/> Setting zero reset the counter.<br/>
 
This property indicates the number of rollovers that were passed in the drive.
 
This property indicates the number of rollovers that were passed in the drive.
 
|TYPE= intger
 
|TYPE= intger
Line 12: Line 12:
 
|DEFAULT= none
 
|DEFAULT= none
 
|SCOPE=Configuration, Task or Terminal
 
|SCOPE=Configuration, Task or Terminal
|LIMITATIONS= Query only, Axis only  
+
|LIMITATIONS= Axis only , Can be set only when the drive is disabled.
 
|EXAMPLE=
 
|EXAMPLE=
 
|SEE ALSO=
 
|SEE ALSO=

Revision as of 06:01, 10 October 2011

There are drives as BOSCH drives where there are two standard IDN defining minimum and maximum values of counts rollover.
Setting zero reset the counter.
This property indicates the number of rollovers that were passed in the drive.

Syntax

?<axis>.CountExtRollover

Availability

From ver 4.7.14

Type

intger

Range

min-max integer

Units

int

Default

none

Scope

Configuration, Task or Terminal

Limitations

Axis only , Can be set only when the drive is disabled.

See Also

Issue 5339Bugzilla icon.png