Difference between revisions of "MC-Basic:axis.SIMULATED"

From SoftMC-Wiki
Jump to: navigation, search
Line 1: Line 1:
 
{{MC-Basic
 
{{MC-Basic
 +
{{Note|With a simulated axis, In case <Ax>.feedback is set to External, then all the position properties (Pfb, Pcmd, Pext) are equal, excluding positionExternalFactor.}}
 +
 
|SHORT FORM=
 
|SHORT FORM=
  
{{Note|With a simulated axis, In case <Ax>.feedback is set to External, then all the position properties (Pfb, Pcmd, Pext) are equal, excluding positionExternalFactor.}}
 
  
 
|SYNTAX=
 
|SYNTAX=

Revision as of 07:42, 31 August 2011

{{MC-Basic

NOTE-Info.svgNOTE
With a simulated axis, In case <Ax>.feedback is set to External, then all the position properties (Pfb, Pcmd, Pext) are equal, excluding positionExternalFactor.

|SHORT FORM=


|SYNTAX= <axis>.Simulated = <expression>

?<axis>.Simulated

|AVAILABILITY= All versions


|DESCRIPTION= This property is used to define the axis mode of operation as simulated or real. In simulated mode, motion commands are not sent to the drives as the axis is not associated with a physical drive. Simulated axes need to be enabled (using <axis>.ENABLE=ON) before a motion command is applied.
       0 (Real)
       1 (Simulated)

|TYPE= Long

|RANGE= 0 or 1

|UNITS=


|DEFAULT= 0

|SCOPE= Configuration, Task or Terminal

|LIMITATIONS= Can only be set during SERCOS communications phase 0.

|EXAMPLE= Xaxis.Simulated=1

|SEE ALSO=

}}