Line 16: Line 16:
 
Bit[1] in motion (0) standing still (1)   
 
Bit[1] in motion (0) standing still (1)   
  
Bit [2-3]  prf_oper
+
Bit [2-3]  (internal flag)=1 if element is breaking
  
 
Bit [4-5]  profile mode (internal flag)=1 if final velocity reached
 
Bit [4-5]  profile mode (internal flag)=1 if final velocity reached

Revision as of 13:36, 17 July 2011

This read-only property queries the motion status of an element. The element status is returned every SERCOS communication cycle and comprises of 32 bits:

Bit[0] motion reached (position or velocity) target (1), target did not reached yet(0)

Bit[1] in motion (0) standing still (1)

Bit [2-3] (internal flag)=1 if element is breaking

Bit [4-5] profile mode (internal flag)=1 if final velocity reached

Bit [6-7] type of profile, see axis.profileType

Bit [8-11] acc_phase

(<element>.motionstatus shr 8) band 0b1111
[0000] = element acceleration is increasing
[0001] = In position
[0010] = acceleration decrease
[0011] = zero acceleration
[0100] = Trapez Linear acceleration is increasing
[0101] = Trapez acceleration satruration
[0110] = Trapez acceleration decreasing
[0111] = Trapez zero acceleration

Bit [12-14] mot_type

Bit [15] doub_mod

Bit [16] sinprg

Bit [17] group_axes

Bit [18-20] allow_proceed

Bit [21-22] unusedH

Bit [23] imm_exp

Bit [24] imm_chng

Bit [25] stopped

Bit [26] interrupted

Bit [27] pending

Bit [28-30] broken_counter

Bit [31] sign

Syntax

none

Availability

All versions

Type

Long