Difference between revisions of "AXY:MC-Basic:group.PROFILERTYPE"
m |
|||
| Line 32: | Line 32: | ||
|DEFAULT= | |DEFAULT= | ||
| − | -1 | + | -1 (from 4.7.3 version only) |
|SCOPE= | |SCOPE= | ||
Revision as of 12:12, 5 June 2011
Defines the profiler-type used in the motion.
- -1 - profile type is defined by the SmoothFactor
- 0 – Velocity based Velocity trapeze (VT)
- 1 – Velocity based Sine acceleration (SA)
- 2 – Time based trapeze acceleration (TA) or velocity trapeze (VT)
- 3 - Constant Velocity profile (one sample acceleration and one sample deceleration)
Axystems:PrfType vs SmoothFactor
Short form
PrfType
Syntax
<group>.profilertype = <numeric expression>
Availability
4.5.25
Type
Long
Range
-1-3
Default
-1 (from 4.7.3 version only)
Scope
Configuration, Task, Terminal
Limitations
Modal/Nodal